Basic Info.
- Model NO.
- PAUT X1/X2/X3
- Battery Run Time
- 2 Batteries Run for 5 Hours
- Wireless Connection
- There Are
- Transport Package
- Wooden Box
- Specification
- 348*277*114 mm
- Trademark
- /
- Origin
- China
- HS Code
- 845611009
- Production Capacity
- 10sets/Month
Packaging & Delivery
- Package Size
- 348.00cm * 227.00cm * 114.00cm
- Package Gross Weight
- 15.000kg
Product Description
Product Description
Product Introduction
Ultrasonic flaw detector is a portable industrial non-destructive testing instrument that can be used quickly, conveniently, and non invasively
Ground to workpiece
Damage and precise detection, measurement, positioning, evaluation, and diagnosis of various internal defects such as cracks, looseness, pores, inclusions, etc Real time color imaging, including A/B/C/D and S scans, helps with defect detection
Explain without misjudging or omitting defects;
Phased array systems can be used in almost any conventional ultrasonic flaw detector for detection applications
Including aerospace, power production, petrochemicals, metal billets, and pipelines
Including supply, pipeline construction and maintenance, structural metals, and general manufacturing
All of these tests will be used in various industrial fields Phased array is commonly used for weld detection, crack detection, and corrosion imaging
Pay more attention to details for professional work
The body is made of high-strength aluminum alloy shell, which is sturdy, durable, and has excellent shielding performance; Large size industrial capacitive screen; Supports a maximum storage capacity of 1TB; 2 hot items
Inserting and unplugging lithium batteries can meet 5-8 hours of working time per day
Product Features
A 1.300Gb DDR bandwidth enables real-time TFM and smoother system operation
2. The 16 bit/100MSPS ADC achieves ultra-high dynamic range, which can be seen as more
Details
3. The special circuit design greatly reduces transmission and reception losses, achieving ultra-high signal-to-noise ratio
4. Equipped with a brand new focusing rule calculator with independent intellectual property rights, it can directly simulate three-dimensional sound field distribution
5. With an emission voltage of up to 200V, it can perfectly
Accurately detect the size of workpieces
6. By simultaneously receiving through 64 channels, it can meet various special application requirements such as surface array and double-sided array
7. FMC data acquisition speed can reach 2GB/S, far exceeding the current portable detection system
Data collection speed
8. It can achieve parallel use of multiple machines and realize the application of large-scale system functions
| PAUT X1 | |||
| Universal parameter | PA configuration | ||
| Dimensions(width x height xthickness) | 348*277*114 mm (13.7*10.9*4.5in) | PA configuration | 32:64 PR 1 |
| weight | Approx. 6.09kg (including 1 battery) | Number of groups | 9 |
| Screen size | 11.6 inches (1920*1080) | digit | 16-bit |
| Touch screen technology | capacitance | A Maximum scanned value | Up to 1600% |
| Operating temperature | -10°-45°C ( 14°-113°F ) | A Maximum number of data points to be scanned | Up to 16384 |
| Storage temperature | -10°-60°C ( 14°-140°F ) (Built-in battery) | The maximum number of focusing law | 8192 |
| Cooling fan | 2 | Digitization frequency | 200MHz |
| Operating temperature | Up to 70% do not cool at 45°C (113°F) | Maximum PRF | 20KHz |
| Battery run time | 2 batteries run for 5 hours | Pulse shape | Bipolar square wave is adjustable |
| Hard disk capacity | 250 GB SSD (Scalable up to 1T) | gain span | 0-80 dB |
| USB 3.0 | 2 | Pulse generator voltage | 100V / 200V |
| Wireless connection | There are | Pulse width | 20ns to 1250ns |
| Video output | Mini DP | System bandwidth | 0.4 MHz to 18 MHz |
| PA channel | There are | Real-time averaging | Up to 64 |
| TCG multi-point acquisition | yes | ||
| TFM / FMC(selectable) | Software feature | ||
| TFM / FMC Feature | TFM / FMC | Use experience | Run smoothl |
| Pulse receiver | 32:64 | Probe database | There are |
| digit | 14 | Wedge database | There are |
| Parallel multi-mode full focus mode TFM | yes | Focusing mode | Depth, range, leve |
| Parallel PA+TFM acquisition | yes | 2D Focusing law calculation | There are |
| TFM Resolution | 1024 x 1024 | Beam overlay display | There are |
| 3D display of workpiece structure | There are | ||
| Remote control | There are | ||
| The PAUT and TFM are displayed simultaneously | There are | ||
| Multimodal TFM simultaneous detection | There are | ||
| 3D Data view | There are | ||
| There ar | There are | ||
| There ar | There are | ||
| Run smoothl | There are | ||
| Support wireless transmission | yes | ||
| PAUT X2 | |||
| Universal parameter | PA configuration | ||
| Dimensions(width x heightx thickness) | 348*277*114 mm (13.7*10.9*4.5in) | PA configuration | 32:128 PR 1 |
| weight | Approx. 6.09kg (including 1 battery) | Number of groups | 8 |
| Screen size | 11.6 inches (1920*1080) | digit | 16-bit |
| Touch screen technology | capacitance | A Maximum scanned value | Up to 1600% |
| Operating temperature | -10°-45°C ( 14°-113°F ) | A Maximum number of data points to be scanned | Up to 16384 |
| Storage temperature | -10°-60°C ( 14°-140°F ) (Built-in battery) | The maximum number of focusing law | 8192 |
| Cooling fan | 2 | Digitization frequency | 200MHz |
| Operating temperature | Up to 70% do not cool at 45°C (113°F) | Maximum PRF | 20KHz |
| Battery run time | 2 batteries run for 5 hours | Pulse shape | Bipolar pulse optional) |
| Hard disk capacity | 250 GB SSD (Scalable up to 1T) | gain span | 0-80 dB |
| USB 3.0 | 2 | Pulse generator voltage | 100V / 200V |
| Wireless connection | There are | Pulse width | 20ns to 1250ns |
| Video output | Mini DP | System bandwidth | 0.4 MHz to 18 MHz |
| PA channel | There are | Real-time averaging | Up to 64 |
| TCG multi-point acquisition | yes | ||
| TFM / FMC(selectable) | Software feature | ||
| TFM / FMC Feature | TFM / FMC | Use experience | Run smoothl |
| Pulse receiver | 32:128 | Probe database | There are |
| digit | 14 | Wedge database | There are |
| Parallel multi-mode full focus mode TFM | yes | Focusing mode | Depth, range, leve |
| Parallel PA+TFM acquisition | yes | 2D Focusing law calculation | There are |
| TFM Resolution | 1024 x 1024 | Beam overlay display | There are |
| 3D display of workpiece structure | There are | ||
| Remote control | There are | ||
| The PAUT and TFM are displayed simultaneously | There are | ||
| Multimodal TFM simultaneous detection | There are | ||
| 3D Data view | There are | ||
| There ar | There are | ||
| There ar | There are | ||
| Run smoothl | There are | ||
| Support wireless transmission | yes | ||
| PAUT X3 | |||
| Universal parameter | PA configuration | ||
| Dimensions(width x height xthickness) | 348*277*114 mm (13.7*10.9*4.5in) | PA configuration | 64:128 PR 1 |
| weight | Approx. 6.19kg (including 1 battery) | Number of groups | Can be upgraded to 4 probes, 8 groups |
| Screen size | 11.6 inches (1920*1080) | Inspection technique | PA |
| Touch screen technology | capacitance | digit | 16-bit |
| Operating temperature | -10°-45°C ( 14°-113°F ) | A Scanning height | Up to 200% |
| Storage temperature | -10°-60°C ( 14°-140°F ) (Built-in battery) | A Maximum number of data points to be scanned | Up to 16384 |
| Cooling fan | 2 | The maximum number of focusing laws | 8192 |
| Operating temperature | Up to 70% do not cool at 45°C (113°F) | Maximum data transmission | 2 GB/s |
| Battery run time | 2 batteries run for 4 hours (hot swappable) | Digitization frequency | 100MHz / 200MHz |
| Hard disk capacity | 256 GB SSD (Scalable up to 1T) | Maximum PRF | 20KHz |
| USB 3.0 | 2 | Pulse shape | Negative square wave pulse/Upgradeable positive |
| Give an alarm | 4 | gain span | and negative square wave pulse |
| Wireless connection | There are | Pulse generator voltage | 0-80 dB |
| Video output | Mini DP | Pulse width | 100V / 200V |
| PA channel | There are | System bandwidth | 20ns to 1250ns |
| Real-time aver | 0.4 MHz to 25 MHz | ||
| gain span | 0-80 dB | ||
| aging | Up to 64 | ||
| TCG multi-point acquisition | yes | ||
| TFM / FMC | Software feature | ||
| TFM / FMC Feature | TFM / FMC | Use experience | Run smoothl |
| Pulse receiver | 64:128 | Automatic probe identification | yes |
| Bit depth | 16 | Automatic scanner recognition | yes |
| Frame rate | 256 x 256: Up to 80Hz | Automatic wedge recognition | yes |
| Parallel multi-mode full focus mode TFM | yes | Focusing mode | True depth, sound path, projection |
| Parallel PA+TFM acquisition | yes | 2D Focusing law calculation | yes |
| TFM Resolution | 1024 x 1024 | Installation wizard | yes |
| A Scan storage | There are | Wireless screen mirroring | yes |
| TFM post-processing support | yes | Wireless remote control | yes |
| S Scan | yes | ||
| Real-time file merge | yes | ||
| 3D Data view | yes | ||
| Support wireless transmission | yes | ||






Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- Phased Array Flaw Detector
- Professional Grade Phased Array Flaw Detector with Extensive Database